- Order number: BS.tp
- Medium type: TP
- Supported load types:
- Blinds
- Shutter
- Blinds/shutter position are stored at 'power down'
- Exception: after setting the device to its ex-factory state
- 8 channels
- 8 objects per channel
- Move
- Step/Stop
- Position
- Angle
- Only for blinds
- 2 variants: 1-byte or 2-byte
- Info Position
- Feedback object, i.e. it sends information to the bus
- Angle Position
- Only for blinds
- Feedback object, i.e. it sends information to the bus
- Frost Alarm
- Only for shutters
- Moves the shutters up after the alarm has been triggered (*)
- The channel (shutters) cannot not be controlled via the other objects as long the alarm is triggered
- Rain Alarm
- Only for shutter
- Moves the shutters down after the alarm has been triggered (*)
- The channel (shutters) cannot not be controlled via the other objects as long the alarm is triggered
- Wind Alarm
- Only for shutter
- Moves the shutters up after the alarm has been triggered (*)
- The channel (shutters) cannot not be controlled via the other objects as long the alarm is triggered
- Intrusion Alarm
- Only for blinds
- While the alarm is triggered: moves the blinds between two fixed positions (*)
- The channel (blinds) cannot not be controlled via the other objects as long the alarm is triggered
- Fire Alarm
- Only for blinds
- Moves the blinds up after the alarm has been triggered (*)
- The channel (blinds) cannot not be controlled via the other objects as long the alarm is triggered
- Triggered alarms are indicated in the channel labels, as:
- 'F' in case of fire (blinds)
- 'I' in case of intrusion (blinds)
- 'W' in case of wind (shutter)
- 'R' in case of rain (shutter)
- 'F': in case of frost (shutter)
- Alarm priority: defines the priority of the alarms per channel
- Shutter: frost > wind > rain or frost > rain > wind
- For blinds this is fixed to fire > intrusion and therefore not available as parameter
(*) : this depends on the alarm priority, see parameter dialog in the device