Released: 20 May 2025, Build 8272
| MD5 Hash: 41de9b912f1367fcf49e83160f932f08 |
Watch the ETS 6.3.1 release party video here!
📈Improvements
User Interface & Functionality
-
Improve Sequence number isolation between devices
Allow "Unload All" (=FactoryReset) also with high secure sequence numbers
Modify the Device Developer check so that it checks for a Manufacturer Tool license instead
Implement a fix for some KNX/IP devices
Improve the licensing workflow while doing multi-selection
The "Close Project" icon has been replaced with a more distinctive icon
Set Last Modified Column Configuration as Default for newly opened Detail View of that type
Add an additional security proxy entry to sidebar application
Make local IpDeviceDiscovery work also if none of the Network Interface Cards has a supported type
ETS + KNX IoT: Bus current in Info; Remove this information for KNX IoT devices
🛠️Bug fixes
User Interface & Functionality
- Project Archive:
- Not reachable webDAV folder
- Archive enumeration fails when subfolder contains empty status.info
- Archive in conflict state after local changes
- Device Compare App not licensed even after adding license
- Export of password protected projects fails, if not opened before
- Loss of Topology Segments and Devices after changing password of secured project
- Moving a device across security domains does not reset programming flags
- Problem when synchronizing group tree
- Removing channel instances which do not exist in usage anymore repeatedly triggers persistence
- IoT Point API:
- Last downloaded time stamp in ETS gets Updated correctly for IoT Point API devices
- Removed filter table from reading Device Info for IoT Point API devices
- Resolved issues related to failure of firmware updates for very large payload sizes
Resolved issue related to pop-up shown related to invalid mDNS discovery responses for IoT Point API - IoT Point API firmware update now considers the sleep cycle of sleepy devices
- Turn programming mode On/Off now considers the sleep cycle for sleepy devices
- For IoT Point API devices the sending association Group Address will be configured first in all cases
- Receiving ICMP errors no longer aborts operations for IoT Point API devices
- If the DefaultValue of a parameter with ParameterType 'Color' is presented as a string (instead of 'Color object'), an error is thrown
- Workspace not correctly saved when closing ETS with the x button of the window
- GroupValue dialog not wide enough for DPT 251.600
- Last value read secure group addresses not visible in group addresses
- Missing Texts at channels and Communication Objects
- Monitor: Custom filters do not work properly
- Parameter dialog: Rounding problem
- "Write value" and "Read value" options are not available in the Building Panel when filter is used
- Security status inconsistency; Some instances show blue shield, while others are blank
- Trying to switch the panel type while in in-place edit mode raises an exception
- Trades: tree doesn't sort in alphabetical order
- Unable to edit IoT Line Name using In-place edit after try to change medium type
- Cloud interface with AccessToken works only once
- The MultiSelection download (RF Fast & Ready) fails if a retransmitter is active
- DCA extremely slow after switching to group objects tab and back and an error occurs
- ETS does not use direct IP connection if device does not support SEARCH_REQUEST_EXTENDED
- Monitor delay time issue
- Support Ex-factory cloud interface
- The application download always breaks after confirmed restart
- ETS tries to contact the media coupler which is currently not downloaded and not in the same segment like the RF Multi interface.
- Newer ETS Version cannot pick up licensing session from < ETS 6.2.2