EITT 4.3 will no longer be updated. Please start using EITT 4.4 instead.
EITT 43, build version 508
Publish date: 18/08/2023
Compared to the build version 503 the following new features and bug corrections are implemented:
- The identity check for USB interfaces will be done on the basis of the KNX serial number instead of the individual address (see also the “Important Note” below).
- The new services M_FUNCPROPCOMMAND, M_FUNCPROPSTATEREAD are now available.
- The CTRL+ALT+C XML clipboard now writes the address extension type element for all extended frames (UseSystemBroadcast=”yes/no”).
- The CTRL+ALT+C XML clipboard now adds the element SecType=”conf” for Sync telegrams.
- The Undo stack will no longer be reset when the .ctl file is saved.
- A change in the automation interface was implemented: EITT will now close automatically if no automation port is open and EITT is in automation mode, even if not all created objects are released.
Important Note:
The previous configuration links for USB interfaces are no more valid in this version and must be reconfigured!
Because the identity of USB interfaces will now be checked based on the KNX serial number instead of the individual address, the configuration of USB interfaces in the “Interface Nickname” Editor must be updated. The previous configuration (linked to the individual address) will no longer work with this EITT version.
EITT 43, build version 503
Publish date: 18/04/2023
Compared to the build version 490 the following new features and bug corrections are implemented:
Local Service Telegrams:
- The maximal possible length of Local Service telegrams was increased to the length of 524 bytes.
- A tooltip will be displayed in the Telegram Properties Window and the Telegram Grid for cEMI Local Service telegrams. The tooltip shows the additional info or (in case of an length error) a corresponding message.
- In case EITT detects an error in the additional info length information, the Local Service telegram will be marked red in the Telegram Properties Window.
Important:
The data in the .ctl file has been changed. Please save your current work before using Eitt 4.3, build 503.
The user is able to open and save .ctl files with previous versions of EITT, but then Local Service telegrams longer than the old max. length will be truncated!
If a telegram sequence contains Local Service telegrams longer than than the old max. length, a hint will be displayed to the user. This hint can be disabled by unchecking in the corresponding dialog.
Security Configuration Table:
- The Security Configuration Table dialog keeps the row order imported from a CSV file as “Custom Order”. An additional button in the dialog window allows the user to sort the rows according to the the custom order and to move rows up or down if the “Custom Order” is displayed.
- As already implemented in earlier EITT versions, the display order can be changed to the other sort orders by clicking in the columns “Address Type”, “Destination Address” or “Serial/Domain” of the header row. EITT saves the selected sort order type in the registry to ensure that the user must choose the preferred sort order only once.
- A bug was corrected that could occur while saving the Security Configuration Table (caused an error on next ctl file loading).
RF busmonitor mode:
EITT is now able to decode RF busmonitor and RF raw frames. The decoded telegram and the busmonitor / raw frame can be displayed in the Tracebuffer depending on the option “Busmonitor Data” in the dialog “Display Trace”. The dialog can be opened via clicking on the menu “Trace”, entry “Telegramstyle”.
Further changes:
- A tooltip was added to the Bus Connection dialog explaining the meaning of the “Bus/Local” option. Additionally, the layer selection is disabled when the “Local” option is set.
- The usage of the following Local Services is now allowed in telegram sequences (in OUT telegrams only), even if the interface is not set to “Local”: 2D CC, 2D 0C, 2D C0.
- The “ctrl +alt +c” XML clipboard now works with USB frames and Local Service telegram frames too.
- The LFN calculation now depends also on the RF serial number.
- Changed user notification when trying to import knxproj files with Modular Application Programs.
EITT 43, build version 490
Publish date: 29/9/2022
Compared to the build version 485 the following new features and bug corrections are implemented:
- Rework of busmonitor data evaluation: EITT now accepts missing additional infos type 3 and 4 in busmonitor mode and then displays empty busmonitor data in the trace buffer. No empty busmonitor data will be displayed, if an RF interface is used and opened in Raw Mode.
- Additional infos will now also be compared in protected sequences.
- Additional infos will now also be copied to the XML clipboard.
- The keys in the Security Configuration Table must not be unique.
- Modification of ‘Bus Connections’ dialog: Deactivation of ‘ChkSum’ option in case of RF and RawMode (with an explaining tooltip).
- The display of FT Flag icon in the trace buffer was changed for FAULTY telegrams, if the FT flag is set and don’t care: The FAULTY telegram will be displayed as received. The FT flag will be displayed without FT flag icon.
EITT 43, build version 485
Publish date: 26/4/2022
Compared to the build version 484 the following bug corrections are implemented:
- Additional Infos can be edited for a selection of telegrams.
- The trace buffer compare function has been improved. Before comparing security features, the telegram content will be checked for differences.
EITT 43, build version 484
Publish date: 8/4/2022
Compared to the build version 483 the following bug corrections are implemented:
- No display of “RQ” when sending USB frames and local service telegrams if the feature “AdditionalInfosEnabled” is active.
- Format of the trace buffer export if the feature “AdditionalInfosEnabled” is active.
- Consistent values in the options dialog for the feature “AdditionalInfosEnabled” at the first start of EITT.
EITT 43, build version 483
Publish date: 14/03/2022
Compared to the build version 480 the following changes are implemented:
- Rework of the additional info fields. It is now possible to define different additional info fields for request and confirmation telegrams.
- It is now possible to import products from password protected ETS6 .knxproj files in the Pixit Header Window.
Further changes:
- Bug correction: The function to enter “TimeToNextTelegram” values was reworked.
EITT 43, build version 480
Publish date: 21/01/2022
Compared to the build version 477 the following changes are implemented:
- Non LinkLayer Local Services can now be sent via connections configured with the ‘Bus’ attribute in the Connection List.
Further changes:
- Local Service telegrams can now be defined in Conformance Test Template XML files.
- The “TimeToNextTelegram” default value for conformance test telegram sequences will now be updated before generating the sequence.