Released 31 January 2022, build 4323
New features
User Interface & Functionality
- Allow import of ETS5 project archive files into ETS6 local store
- Support of Symlink folders in the Project Archive
- Enhancement of the update notification dialog
- Windows 11 support
ETS SDK
- N/A
Improvements
User Interface & Functionality
- User Experience
- Add panel names to tab headers
- Dashboard tabs display the current location (Overview, Archive, etc.)
- Allow deleting a project version from the project archive
- Separated back button in the navigation when having more than 1 Level of Drilldown
- Revised workflow when an interface is in used in the group monitor
- EIBlib/IP default connection type value set to 'TCP'
- Extended handling of non-unique KNX Serial Numbers
- Extended handling of devices reporting problems with the Extended Memory Services
- KNX Secure
- N/A
Bug fixes
User Interface & Functionality
- KNX Secure
- If a group object has the 'Security required' flag set, it shall be displayed as 'Secure'
- Secure Loading of a specific KNX/IP Interface via Bus not possible
- Secure IP Tunneling connection does not clean up properly
- Group Address security indication is not correctly reset in sidebar when the query dialog is cancelled
- Incorrect handling when disabling security on an IP device if it does not support tunneling
- Download fails if securely linked device is parked
- Not all secure properties of a device are copied when copying a secure device
- User Experience
- Reading a value of a group address fails to start the group monitor
- When opening the group monitor, an exception is thrown in some cases
- When closing the monitor options dialog an error was shown
- ETS does not start if the project archive directory is not accessible
- ETS does not start if the Online Catalog needs to be updated and no network is available
- Pending operations not shown when starting a download
- Completed downloads do not move to history
- The download history lists the latest operations on the bottom
- The option 'Slowed bus communication' does not work properly
- Line scan does not list all results
- Direct IP connection does not work if device reports BCU1 mask version
- Download of specific IP interfaces required a timer increase
- A specific device plug-in crashes ETS if no bus connection is selected
- Incorrect handling when trying to set the individual address of a specific IP interface
- A specific device plug-in does not get a bus connection and crashes
- EIBlib/IP connection throws a SocketException on close
- RF Segments get the same Domain Address when added below the Backbone Topology node
- Not possible to download some devices requiring a specific plug-in and external software (error message HRESULT: 0x800706F7)
- The connection manager stops refreshing
- Incorrect error message shown instead of the actual error message when something incorrect happens on the routing interface of an IP device
- The project connection is not refreshed in the sidebar when changed
- A customized toolbar does not persist the customization
- An ETS App cannot be started from toolbar under certain conditions
- Not possible to send a value for group addresses with Datapoint Types 7.002 - 7.007
- ETS closes during online operations in some rare cases
- Incorrect handling when trying to read device information and the device does not exist
- Group Address cannot be set to x/y/0 via sidebar
- When copying devices using the Extended Copy app across projects, associations are lost
- Copy free group ranges can lead to misplaced group addresses
- Group flag is not cleared when changing range of free group range
- An option in the Replace Device app is unusable
- Links for the help centre are not language dependent
- The taskbar icon remains yellow after warning
- The taskbar icon does not display the correct progress
- Each ETS instance has incorrectly its own 'Recently used projects'
- Missing Icons in some dialogs
- When closing a panel, then the entire ETS window gets quickly resized
- Problems with a specific ETS App which leads to tool diagnostic not working properly
- Opening a project changes the tab order
- Importing projects occasionally lead to defect ProjectStore
- Project cannot be locked and unlocked in the same dialog in the Project Archive
- Online Installation diagnostic wizard cannot be closed
- Restart problems when changing ETS language
- 'Backup Copy' cannot be cancelled
- Incorrect RF Domain Address after Undo/Redo operations
- Undo of moving RF line does not restore the Domain Address
- Incorrect initial button selection in the product import workflow
- ETS runs always in compatibility mode even if it is deactivated
- The standalone diagnostic wizard does not start in some rare cases
- Panel content cannot be switched between ETS Apps
- Back and forth navigation does not work correctly in the 'Diagnostics' panel
- Occasional error messages when using the list view
- The parameter dialog is not properly updated in some cases
- The dynamic folders do not show the correct results in some rare cases
- Inplace edit in the list view causes an exception
- Keyboard navigation in Detail view and inline editing mode does not work
- Fix binding redirects of the 'Ionic.Zip' library needed by some DCAs
ETS SDK
- N/A